Distributed Spare (dRAID) Feature

This patch adds a new top-level vdev type called dRAID, which stands
for Distributed parity RAID.  This pool configuration allows all dRAID
vdevs to participate when rebuilding to a distributed hot spare device.
This can substantially reduce the total time required to restore full
parity to pool with a failed device.

A dRAID pool can be created using the new top-level `draid` type.
Like `raidz`, the desired redundancy is specified after the type:
`draid[1,2,3]`.  No additional information is required to create the
pool and reasonable default values will be chosen based on the number
of child vdevs in the dRAID vdev.

    zpool create <pool> draid[1,2,3] <vdevs...>

Unlike raidz, additional optional dRAID configuration values can be
provided as part of the draid type as colon separated values. This
allows administrators to fully specify a layout for either performance
or capacity reasons.  The supported options include:

    zpool create <pool> \
        draid[<parity>][:<data>d][:<children>c][:<spares>s] \
        <vdevs...>

    - draid[parity]       - Parity level (default 1)
    - draid[:<data>d]     - Data devices per group (default 8)
    - draid[:<children>c] - Expected number of child vdevs
    - draid[:<spares>s]   - Distributed hot spares (default 0)

Abbreviated example `zpool status` output for a 68 disk dRAID pool
with two distributed spares using special allocation classes.

```
  pool: tank
 state: ONLINE
config:

    NAME                  STATE     READ WRITE CKSUM
    slag7                 ONLINE       0     0     0
      draid2:8d:68c:2s-0  ONLINE       0     0     0
        L0                ONLINE       0     0     0
        L1                ONLINE       0     0     0
        ...
        U25               ONLINE       0     0     0
        U26               ONLINE       0     0     0
        spare-53          ONLINE       0     0     0
          U27             ONLINE       0     0     0
          draid2-0-0      ONLINE       0     0     0
        U28               ONLINE       0     0     0
        U29               ONLINE       0     0     0
        ...
        U42               ONLINE       0     0     0
        U43               ONLINE       0     0     0
    special
      mirror-1            ONLINE       0     0     0
        L5                ONLINE       0     0     0
        U5                ONLINE       0     0     0
      mirror-2            ONLINE       0     0     0
        L6                ONLINE       0     0     0
        U6                ONLINE       0     0     0
    spares
      draid2-0-0          INUSE     currently in use
      draid2-0-1          AVAIL
```

When adding test coverage for the new dRAID vdev type the following
options were added to the ztest command.  These options are leverages
by zloop.sh to test a wide range of dRAID configurations.

    -K draid|raidz|random - kind of RAID to test
    -D <value>            - dRAID data drives per group
    -S <value>            - dRAID distributed hot spares
    -R <value>            - RAID parity (raidz or dRAID)

The zpool_create, zpool_import, redundancy, replacement and fault
test groups have all been updated provide test coverage for the
dRAID feature.

Co-authored-by: Isaac Huang <he.huang@intel.com>
Co-authored-by: Mark Maybee <mmaybee@cray.com>
Co-authored-by: Don Brady <don.brady@delphix.com>
Co-authored-by: Matthew Ahrens <mahrens@delphix.com>
Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Mark Maybee <mmaybee@cray.com>
Reviewed-by: Matt Ahrens <matt@delphix.com>
Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov>
Closes #10102
This commit is contained in:
Brian Behlendorf
2020-11-13 13:51:51 -08:00
committed by GitHub
parent a724db0374
commit b2255edcc0
153 changed files with 10203 additions and 1882 deletions
+94 -32
View File
@@ -60,6 +60,7 @@
#include <sys/vdev_rebuild.h>
#include <sys/vdev_trim.h>
#include <sys/vdev_disk.h>
#include <sys/vdev_draid.h>
#include <sys/metaslab.h>
#include <sys/metaslab_impl.h>
#include <sys/mmp.h>
@@ -3681,7 +3682,14 @@ spa_ld_trusted_config(spa_t *spa, spa_import_type_t type,
/*
* Build a new vdev tree from the trusted config
*/
VERIFY(spa_config_parse(spa, &mrvd, nv, NULL, 0, VDEV_ALLOC_LOAD) == 0);
error = spa_config_parse(spa, &mrvd, nv, NULL, 0, VDEV_ALLOC_LOAD);
if (error != 0) {
nvlist_free(mos_config);
spa_config_exit(spa, SCL_ALL, FTAG);
spa_load_failed(spa, "spa_config_parse failed [error=%d]",
error);
return (spa_vdev_err(rvd, VDEV_AUX_CORRUPT_DATA, error));
}
/*
* Vdev paths in the MOS may be obsolete. If the untrusted config was
@@ -5631,7 +5639,7 @@ spa_create(const char *pool, nvlist_t *nvroot, nvlist_t *props,
uint64_t txg = TXG_INITIAL;
nvlist_t **spares, **l2cache;
uint_t nspares, nl2cache;
uint64_t version, obj;
uint64_t version, obj, ndraid = 0;
boolean_t has_features;
boolean_t has_encryption;
boolean_t has_allocclass;
@@ -5753,8 +5761,8 @@ spa_create(const char *pool, nvlist_t *nvroot, nvlist_t *props,
if (error == 0 &&
(error = vdev_create(rvd, txg, B_FALSE)) == 0 &&
(error = spa_validate_aux(spa, nvroot, txg,
VDEV_ALLOC_ADD)) == 0) {
(error = vdev_draid_spare_create(nvroot, rvd, &ndraid, 0)) == 0 &&
(error = spa_validate_aux(spa, nvroot, txg, VDEV_ALLOC_ADD)) == 0) {
/*
* instantiate the metaslab groups (this will dirty the vdevs)
* we can no longer error exit past this point
@@ -5895,6 +5903,9 @@ spa_create(const char *pool, nvlist_t *nvroot, nvlist_t *props,
spa_sync_props(props, tx);
}
for (int i = 0; i < ndraid; i++)
spa_feature_incr(spa, SPA_FEATURE_DRAID, tx);
dmu_tx_commit(tx);
spa->spa_sync_on = B_TRUE;
@@ -6403,13 +6414,26 @@ spa_reset(const char *pool)
* ==========================================================================
*/
/*
* This is called as a synctask to increment the draid feature flag
*/
static void
spa_draid_feature_incr(void *arg, dmu_tx_t *tx)
{
spa_t *spa = dmu_tx_pool(tx)->dp_spa;
int draid = (int)(uintptr_t)arg;
for (int c = 0; c < draid; c++)
spa_feature_incr(spa, SPA_FEATURE_DRAID, tx);
}
/*
* Add a device to a storage pool.
*/
int
spa_vdev_add(spa_t *spa, nvlist_t *nvroot)
{
uint64_t txg;
uint64_t txg, ndraid = 0;
int error;
vdev_t *rvd = spa->spa_root_vdev;
vdev_t *vd, *tvd;
@@ -6438,8 +6462,23 @@ spa_vdev_add(spa_t *spa, nvlist_t *nvroot)
return (spa_vdev_exit(spa, vd, txg, EINVAL));
if (vd->vdev_children != 0 &&
(error = vdev_create(vd, txg, B_FALSE)) != 0)
(error = vdev_create(vd, txg, B_FALSE)) != 0) {
return (spa_vdev_exit(spa, vd, txg, error));
}
/*
* The virtual dRAID spares must be added after vdev tree is created
* and the vdev guids are generated. The guid of their assoicated
* dRAID is stored in the config and used when opening the spare.
*/
if ((error = vdev_draid_spare_create(nvroot, vd, &ndraid,
rvd->vdev_children)) == 0) {
if (ndraid > 0 && nvlist_lookup_nvlist_array(nvroot,
ZPOOL_CONFIG_SPARES, &spares, &nspares) != 0)
nspares = 0;
} else {
return (spa_vdev_exit(spa, vd, txg, error));
}
/*
* We must validate the spares and l2cache devices after checking the
@@ -6452,7 +6491,7 @@ spa_vdev_add(spa_t *spa, nvlist_t *nvroot)
* If we are in the middle of a device removal, we can only add
* devices which match the existing devices in the pool.
* If we are in the middle of a removal, or have some indirect
* vdevs, we can not add raidz toplevels.
* vdevs, we can not add raidz or dRAID top levels.
*/
if (spa->spa_vdev_removal != NULL ||
spa->spa_removing_phys.sr_prev_indirect_vdev != -1) {
@@ -6462,10 +6501,10 @@ spa_vdev_add(spa_t *spa, nvlist_t *nvroot)
tvd->vdev_ashift != spa->spa_max_ashift) {
return (spa_vdev_exit(spa, vd, txg, EINVAL));
}
/* Fail if top level vdev is raidz */
if (tvd->vdev_ops == &vdev_raidz_ops) {
/* Fail if top level vdev is raidz or a dRAID */
if (vdev_get_nparity(tvd) != 0)
return (spa_vdev_exit(spa, vd, txg, EINVAL));
}
/*
* Need the top level mirror to be
* a mirror of leaf vdevs only
@@ -6505,6 +6544,19 @@ spa_vdev_add(spa_t *spa, nvlist_t *nvroot)
spa->spa_l2cache.sav_sync = B_TRUE;
}
/*
* We can't increment a feature while holding spa_vdev so we
* have to do it in a synctask.
*/
if (ndraid != 0) {
dmu_tx_t *tx;
tx = dmu_tx_create_assigned(spa->spa_dsl_pool, txg);
dsl_sync_task_nowait(spa->spa_dsl_pool, spa_draid_feature_incr,
(void *)(uintptr_t)ndraid, tx);
dmu_tx_commit(tx);
}
/*
* We have to be careful when adding new vdevs to an existing pool.
* If other threads start allocating from these vdevs before we
@@ -6615,14 +6667,27 @@ spa_vdev_attach(spa_t *spa, uint64_t guid, nvlist_t *nvroot, int replacing,
if (oldvd->vdev_top->vdev_islog && newvd->vdev_isspare)
return (spa_vdev_exit(spa, newrootvd, txg, ENOTSUP));
/*
* A dRAID spare can only replace a child of its parent dRAID vdev.
*/
if (newvd->vdev_ops == &vdev_draid_spare_ops &&
oldvd->vdev_top != vdev_draid_spare_get_parent(newvd)) {
return (spa_vdev_exit(spa, newrootvd, txg, ENOTSUP));
}
if (rebuild) {
/*
* For rebuilds, the parent vdev must support reconstruction
* For rebuilds, the top vdev must support reconstruction
* using only space maps. This means the only allowable
* parents are the root vdev or a mirror vdev.
* vdevs types are the root vdev, a mirror, or dRAID.
*/
if (pvd->vdev_ops != &vdev_mirror_ops &&
pvd->vdev_ops != &vdev_root_ops) {
tvd = pvd;
if (pvd->vdev_top != NULL)
tvd = pvd->vdev_top;
if (tvd->vdev_ops != &vdev_mirror_ops &&
tvd->vdev_ops != &vdev_root_ops &&
tvd->vdev_ops != &vdev_draid_ops) {
return (spa_vdev_exit(spa, newrootvd, txg, ENOTSUP));
}
}
@@ -6915,14 +6980,20 @@ spa_vdev_detach(spa_t *spa, uint64_t guid, uint64_t pguid, int replace_done)
}
/*
* If we are detaching the original disk from a spare, then it implies
* that the spare should become a real disk, and be removed from the
* active spare list for the pool.
* If we are detaching the original disk from a normal spare, then it
* implies that the spare should become a real disk, and be removed
* from the active spare list for the pool. dRAID spares on the
* other hand are coupled to the pool and thus should never be removed
* from the spares list.
*/
if (pvd->vdev_ops == &vdev_spare_ops &&
vd->vdev_id == 0 &&
pvd->vdev_child[pvd->vdev_children - 1]->vdev_isspare)
unspare = B_TRUE;
if (pvd->vdev_ops == &vdev_spare_ops && vd->vdev_id == 0) {
vdev_t *last_cvd = pvd->vdev_child[pvd->vdev_children - 1];
if (last_cvd->vdev_isspare &&
last_cvd->vdev_ops != &vdev_draid_spare_ops) {
unspare = B_TRUE;
}
}
/*
* Erase the disk labels so the disk can be used for other things.
@@ -8013,18 +8084,9 @@ spa_async_thread(void *arg)
/*
* If any devices are done replacing, detach them.
*/
if (tasks & SPA_ASYNC_RESILVER_DONE)
if (tasks & SPA_ASYNC_RESILVER_DONE ||
tasks & SPA_ASYNC_REBUILD_DONE) {
spa_vdev_resilver_done(spa);
/*
* If any devices are done replacing, detach them. Then if no
* top-level vdevs are rebuilding attempt to kick off a scrub.
*/
if (tasks & SPA_ASYNC_REBUILD_DONE) {
spa_vdev_resilver_done(spa);
if (!vdev_rebuild_active(spa->spa_root_vdev))