mirror_zfs/man/man5/vdev_id.conf.5

252 lines
6.6 KiB
Groff
Raw Normal View History

.\"
.\" This file and its contents are supplied under the terms of the
.\" Common Development and Distribution License ("CDDL"), version 1.0.
.\" You may only use this file in accordance with the terms of version
.\" 1.0 of the CDDL.
.\"
.\" A full copy of the text of the CDDL should have accompanied this
.\" source. A copy of the CDDL is also available via the Internet at
.\" http://www.illumos.org/license/CDDL.
.\"
.Dd May 26, 2021
.Dt VDEV_ID.CONF 5
.Os
.
.Sh NAME
.Nm vdev_id.conf
.Nd Configuration file for vdev_id
.Sh DESCRIPTION
.Nm
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
is the configuration file for
.Nm vdev_id Ns Sy (8) .
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
It controls the default behavior of
.Nm vdev_id Ns Sy (8)
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
while it is mapping a disk device name to an alias.
.Pp
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
The
.Nm
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
file uses a simple format consisting of a keyword followed by one or
more values on a single line.
Any line not beginning with a recognized keyword is ignored.
Comments may optionally begin with a hash character.
.Pp
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
The following keywords and values are used.
.Bl -tag -width "-h"
.It Sy alias Ar name Ar devlink
Maps a device link in the
.Pa /dev
directory hierarchy to a new device name.
The udev rule defining the device link must have run prior to
.Nm vdev_id Ns Sy (8) .
A defined alias takes precedence over a topology-derived name, but the
two naming methods can otherwise coexist.
For example, one might name drives in a JBOD with the
.Sy sas_direct
topology while naming an internal L2ARC device with an alias.
.Pp
.Ar name
is the name of the link to the device that will by created under
.Pa /dev/disk/by-vdev .
.Pp
.Ar devlink
is the name of the device link that has already been
defined by udev.
This may be an absolute path or the base filename.
.
.It Sy channel [ Ns Ar pci_slot ] Ar port Ar name
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
Maps a physical path to a channel name (typically representing a single
disk enclosure).
.
.It Sy enclosure_symlinks Sy yes Ns | Ns Sy no
Additionally create
.Pa /dev/by-enclosure
symlinks to the disk enclosure
.Em sg
devices using the naming scheme from
.Pa vdev_id.conf .
.Sy enclosure_symlinks
is only allowed for
.Sy sas_direct
mode.
.
.It Sy enclosure_symlinks_prefix Ar prefix
Specify the prefix for the enclosure symlinks in the form
.Pa /dev/by-enclosure/ Ns Ao Ar prefix Ac Ns - Ns Ao Ar channel Ac Ns Aq Ar num
.Pp
Defaults to
.Dq Em enc .
.
.It Sy slot Ar prefix Ar new Op Ar channel
Maps a disk slot number as reported by the operating system to an
alternative slot number.
If the
.Ar channel
parameter is specified
then the mapping is only applied to slots in the named channel,
otherwise the mapping is applied to all channels.
The first-specified
.Ar slot
rule that can match a slot takes precedence.
Therefore a channel-specific mapping for a given slot should generally appear
before a generic mapping for the same slot.
In this way a custom mapping may be applied to a particular channel
and a default mapping applied to the others.
.
.It Sy multipath Sy yes Ns | Ns Sy no
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
Specifies whether
.Nm vdev_id Ns Sy (8)
will handle only dm-multipath devices.
If set to
.Sy yes
then
.Nm vdev_id Ns Sy (8)
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
will examine the first running component disk of a dm-multipath
device as provided by the driver command to determine the physical path.
.
.It Sy topology Sy sas_direct Ns | Ns Sy sas_switch Ns | Ns Sy scsi
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
Identifies a physical topology that governs how physical paths are
mapped to channels:
.Bl -tag -compact -width "sas_direct and scsi"
.It Sy sas_direct No and Sy scsi
channels are uniquely identified by a PCI slot and HBA port number
.It Sy sas_switch
channels are uniquely identified by a SAS switch port number
.El
.
.It Sy phys_per_port Ar num
Specifies the number of PHY devices associated with a SAS HBA port or SAS
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
switch port.
.Nm vdev_id Ns Sy (8)
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
internally uses this value to determine which HBA or switch port a
device is connected to.
The default is
.Sy 4 .
.
.It Sy slot Sy bay Ns | Ns Sy phy Ns | Ns Sy port Ns | Ns Sy id Ns | Ns Sy lun Ns | Ns Sy ses
Specifies from which element of a SAS identifier the slot number is
taken.
The default is
.Sy bay :
.Bl -tag -compact -width "port"
.It Sy bay
read the slot number from the bay identifier.
.It Sy phy
read the slot number from the phy identifier.
.It Sy port
use the SAS port as the slot number.
.It Sy id
use the scsi id as the slot number.
.It Sy lun
use the scsi lun as the slot number.
.It Sy ses
use the SCSI Enclosure Services (SES) enclosure device slot number,
as reported by
.Xr sg_ses 8 .
Intended for use only on systems where
.Sy bay
is unsupported,
noting that
.Sy port
and
.Sy id
may be unstable across disk replacement.
.El
.El
.
.Sh FILES
.Bl -tag -width "-v v"
.It Pa /etc/zfs/vdev_id.conf
The configuration file for
.Nm vdev_id Ns Sy (8) .
.El
.
.Sh EXAMPLES
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
A non-multipath configuration with direct-attached SAS enclosures and an
arbitrary slot re-mapping:
.Bd -literal -offset Ds
multipath no
topology sas_direct
phys_per_port 4
slot bay
# PCI_SLOT HBA PORT CHANNEL NAME
channel 85:00.0 1 A
channel 85:00.0 0 B
channel 86:00.0 1 C
channel 86:00.0 0 D
# Custom mapping for Channel A
# Linux Mapped
# Slot Slot Channel
slot 1 7 A
slot 2 10 A
slot 3 3 A
slot 4 6 A
# Default mapping for B, C, and D
slot 1 4
slot 2 2
slot 3 1
slot 4 3
.Ed
.Pp
A SAS-switch topology.
Note, that the
.Ar channel
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
keyword takes only two arguments in this example.
.Bd -literal -offset Ds
topology sas_switch
# SWITCH PORT CHANNEL NAME
channel 1 A
channel 2 B
channel 3 C
channel 4 D
.Ed
.Pp
A multipath configuration.
Note that channel names have multiple
Add vdev_id for JBOD-friendly udev aliases vdev_id parses the file /etc/zfs/vdev_id.conf to map a physical path in a storage topology to a channel name. The channel name is combined with a disk enclosure slot number to create an alias that reflects the physical location of the drive. This is particularly helpful when it comes to tasks like replacing failed drives. Slot numbers may also be re-mapped in case the default numbering is unsatisfactory. The drive aliases will be created as symbolic links in /dev/disk/by-vdev. The only currently supported topologies are sas_direct and sas_switch: o sas_direct - a channel is uniquely identified by a PCI slot and a HBA port o sas_switch - a channel is uniquely identified by a SAS switch port A multipath mode is supported in which dm-mpath devices are handled by examining the first running component disk, as reported by 'multipath -l'. In multipath mode the configuration file should contain a channel definition with the same name for each path to a given enclosure. vdev_id can replace the existing zpool_id script on systems where the storage topology conforms to sas_direct or sas_switch. The script could be extended to support other topologies as well. The advantage of vdev_id is that it is driven by a single static input file that can be shared across multiple nodes having a common storage toplogy. zpool_id, on the other hand, requires a unique /etc/zfs/zdev.conf per node and a separate slot-mapping file. However, zpool_id provides the flexibility of using any device names that show up in /dev/disk/by-path, so it may still be needed on some systems. vdev_id's functionality subsumes that of the sas_switch_id script, and it is unlikely that anyone is using it, so sas_switch_id is removed. Finally, /dev/disk/by-vdev is added to the list of directories that 'zpool import' will scan. Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #713
2012-04-21 04:32:30 +04:00
definitions - one per physical path.
.Bd -literal -offset Ds
multipath yes
# PCI_SLOT HBA PORT CHANNEL NAME
channel 85:00.0 1 A
channel 85:00.0 0 B
channel 86:00.0 1 A
channel 86:00.0 0 B
.Ed
.Pp
A configuration with enclosure_symlinks enabled.
.Bd -literal -offset Ds
multipath yes
enclosure_symlinks yes
# PCI_ID HBA PORT CHANNEL NAME
channel 05:00.0 1 U
channel 05:00.0 0 L
channel 06:00.0 1 U
channel 06:00.0 0 L
.Ed
.Pp
In addition to the disks symlinks, this configuration will create:
.Bd -literal -offset Ds
/dev/by-enclosure/enc-L0
/dev/by-enclosure/enc-L1
/dev/by-enclosure/enc-U0
/dev/by-enclosure/enc-U1
.Ed
.Pp
A configuration using device link aliases.
.Bd -literal -offset Ds
# by-vdev
# name fully qualified or base name of device link
alias d1 /dev/disk/by-id/wwn-0x5000c5002de3b9ca
alias d2 wwn-0x5000c5002def789e
.Ed
.
.Sh SEE ALSO
.Xr vdev_id 8