mirror_zfs/cmd/zpool/Makefile.am
Tony Hutter 5e3085e360 Add SMART self-test results to zpool status -c
Add in SMART self-test results to zpool status|iostat -c.  This
works for both SAS and SATA drives.

Also, add plumbing to allow the 'smart' script to take smartctl
output from a directory of output text files instead of running
it against the vdevs.

Reviewed-by: Giuseppe Di Natale <dinatale2@llnl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #7178
2018-03-14 16:10:37 -07:00

124 lines
2.1 KiB
Makefile

include $(top_srcdir)/config/Rules.am
DEFAULT_INCLUDES += \
-I$(top_srcdir)/include \
-I$(top_srcdir)/lib/libspl/include
sbin_PROGRAMS = zpool
zpool_SOURCES = \
zpool_iter.c \
zpool_main.c \
zpool_util.c \
zpool_util.h \
zpool_vdev.c
zpool_LDADD = \
$(top_builddir)/lib/libnvpair/libnvpair.la \
$(top_builddir)/lib/libuutil/libuutil.la \
$(top_builddir)/lib/libzpool/libzpool.la \
$(top_builddir)/lib/libzfs/libzfs.la \
$(top_builddir)/lib/libzfs_core/libzfs_core.la \
-lm $(LIBBLKID)
zpoolconfdir = $(sysconfdir)/zfs/zpool.d
zpoolexecdir = $(libexecdir)/zfs/zpool.d
EXTRA_DIST = zpool.d/README
dist_zpoolexec_SCRIPTS = \
zpool.d/enc \
zpool.d/encdev \
zpool.d/fault_led \
zpool.d/iostat \
zpool.d/iostat-1s \
zpool.d/iostat-10s \
zpool.d/label \
zpool.d/locate_led \
zpool.d/lsblk \
zpool.d/media \
zpool.d/model \
zpool.d/serial \
zpool.d/ses \
zpool.d/size \
zpool.d/slaves \
zpool.d/slot \
zpool.d/smart \
zpool.d/smartx \
zpool.d/temp \
zpool.d/health \
zpool.d/r_proc \
zpool.d/w_proc \
zpool.d/r_ucor \
zpool.d/w_ucor \
zpool.d/nonmed \
zpool.d/defect \
zpool.d/hours_on \
zpool.d/realloc \
zpool.d/rep_ucor \
zpool.d/cmd_to \
zpool.d/pend_sec \
zpool.d/off_ucor \
zpool.d/ata_err \
zpool.d/nvme_err \
zpool.d/pwr_cyc \
zpool.d/upath \
zpool.d/vendor \
zpool.d/smart_test \
zpool.d/test_type \
zpool.d/test_status \
zpool.d/test_progress \
zpool.d/test_ended
zpoolconfdefaults = \
enc \
encdev \
fault_led \
iostat \
iostat-1s \
iostat-10s \
label \
locate_led \
lsblk \
media \
model \
serial \
ses \
size \
slaves \
slot \
smart \
smartx \
temp \
health \
r_proc \
w_proc \
r_ucor \
w_ucor \
nonmed \
defect \
hours_on \
realloc \
rep_ucor \
cmd_to \
pend_sec \
off_ucor \
ata_err \
nvme_err \
pwr_cyc \
upath \
vendor \
smart_test \
test_type \
test_status \
test_progress \
test_ended
install-data-hook:
$(MKDIR_P) "$(DESTDIR)$(zpoolconfdir)"
for f in $(zpoolconfdefaults); do \
test -f "$(DESTDIR)$(zpoolconfdir)/$${f}" -o \
-L "$(DESTDIR)$(zpoolconfdir)/$${f}" || \
ln -s "$(zpoolexecdir)/$${f}" "$(DESTDIR)$(zpoolconfdir)"; \
done