#!/bin/sh # shellcheck disable=SC2154 # # Send notification in response to a DATA error. # # Only one notification per ZED_NOTIFY_INTERVAL_SECS will be sent for a given # class/pool/[vdev] combination. This protects against spamming the recipient # should multiple events occur together in time for the same pool/[vdev]. # # Exit codes: # 0: notification sent # 1: notification failed # 2: notification not configured # 3: notification suppressed # 9: internal error [ -f "${ZED_ZEDLET_DIR}/zed.rc" ] && . "${ZED_ZEDLET_DIR}/zed.rc" . "${ZED_ZEDLET_DIR}/zed-functions.sh" [ -n "${ZEVENT_POOL}" ] || exit 9 [ -n "${ZEVENT_SUBCLASS}" ] || exit 9 [ -n "${ZED_NOTIFY_DATA}" ] || exit 3 rate_limit_tag="${ZEVENT_POOL};${ZEVENT_VDEV_GUID:-0};${ZEVENT_SUBCLASS};notify" zed_rate_limit "${rate_limit_tag}" || exit 3 umask 077 note_subject="ZFS ${ZEVENT_SUBCLASS} error for ${ZEVENT_POOL} on $(hostname)" note_pathname="$(mktemp)" { echo "ZFS has detected a data error:" echo echo " eid: ${ZEVENT_EID}" echo " class: ${ZEVENT_SUBCLASS}" echo " host: $(hostname)" echo " time: ${ZEVENT_TIME_STRING}" echo " error: ${ZEVENT_ZIO_ERR}" echo " objid: ${ZEVENT_ZIO_OBJSET}:${ZEVENT_ZIO_OBJECT}" echo " pool: ${ZEVENT_POOL}" } > "${note_pathname}" zed_notify "${note_subject}" "${note_pathname}"; rv=$? rm -f "${note_pathname}" exit "${rv}"