Commit Graph

6 Commits

Author SHA1 Message Date
Tony Hutter
8720e9e748 Add -c to zpool iostat & status to run command
This patch adds a command (-c) option to zpool status and zpool iostat.  The
-c option allows you to run an arbitrary command on each vdev and display
the first line of output in zpool status/iostat.  The environment vars
VDEV_PATH and VDEV_UPATH are set to the vdev's path and "underlying path"
before running the command.  For device mapper, multipath, or partitioned
vdevs, VDEV_UPATH is the actual underlying /dev/sd* disk.  This can be useful
if the command you're running requires a /dev/sd* device.

The patch also uses /sys/block/<dev>/slaves/ to lookup the underlying device
instead of using libdevmapper.  This not only removes the libdevmapper
requirement at build time, but also allows you to resolve device mapper
devices without being root.  This means that UDEV_UPATH get set correctly
when running zpool status/iostat as an unprivileged user.

Example:

$ zpool status -c 'echo I am $VDEV_PATH, $VDEV_UPATH'

NAME        STATE     READ WRITE CKSUM
mypool      ONLINE       0     0     0
  mirror-0  ONLINE       0     0     0
    mpatha  ONLINE       0     0     0  I am /dev/mapper/mpatha, /dev/sdc
    sdb     ONLINE       0     0     0  I am /dev/sdb1, /dev/sdb

Reviewed-by: Giuseppe Di Natale <dinatale2@llnl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #5368
2016-11-29 14:45:38 -07:00
Don Brady
976246fadd Add illumos FMD ZFS logic to ZED -- phase 2
The phase 2 work primarily entails the Diagnosis Engine and
the Retire Agent modules. It also includes infrastructure
to support a crude FMD environment to host these modules.

The Diagnosis Engine consumes I/O and checksum ereports and
feeds them into a SERD engine which will generate a corres-
ponding fault diagnosis when the SERD engine fires. All the
diagnosis state data is collected into cases, one case per
vdev being tracked.

The Retire Agent responds to diagnosed faults by isolating
the faulty VDEV. It will notify the ZFS kernel module of
the new VDEV state (degraded or faulted). This agent is
also responsible for managing hot spares across pools.
When it encounters a device fault or a device removal it
replaces the device with an appropriate spare if available.

Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Don Brady <don.brady@intel.com>
Closes #5343
2016-11-07 15:01:38 -08:00
Tony Hutter
1ad9de6d08 Allow autoreplace even when enclosure LED sysfs entries don't exist
The previous autoreplace code assumed that if you were using autoreplace, then
you also had the enclosure SES driver loaded.  This could lead to autoreplace
not working if the SES driver wasn't loaded, or if it wasn't creating the
proper enclosure_device symlinks (which has happened).  This patch removes
that assumption.

Reviewed by: Don Brady <don.brady@intel.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #5363
2016-11-04 13:34:13 -07:00
Tony Hutter
1bbd877049 Turn on/off enclosure slot fault LED even when disk isn't present
Previously when a drive faulted, the statechange-led.sh script would lookup
the drive's LED sysfs entry in /sys/block/sd*/device/enclosure_device, and
turn it on.  During testing we noticed that if you pulled out a drive, or if
the drive was so badly broken that it no longer appeared to Linux, that the
/sys/block/sd* path would be removed, and the script could not lookup the
LED entry.

To fix this, this patch looks up the disks's more persistent
"/sys/class/enclosure/X:X:X:X/Slot N" LED sysfs path at pool import.  It then
passes that path to the statechange-led script to use, rather than having the
script look it up on the fly.  This allows the script to turn on/off the slot
LEDs even when the drive is missing.

Closes #5309 
Closes #2375
2016-10-24 10:45:59 -07:00
Tony Hutter
6078881aa1 Multipath autoreplace, control enclosure LEDs, event rate limiting
1. Enable multipath autoreplace support for FMA.

This extends FMA autoreplace to work with multipath disks.  This
requires libdevmapper to be installed at build time.

2. Turn on/off fault LEDs when VDEVs become degraded/faulted/online

Set ZED_USE_ENCLOSURE_LEDS=1 in zed.rc to have ZED turn on/off the enclosure
LED for a drive when a drive becomes FAULTED/DEGRADED.  Your enclosure must
be supported by the Linux SES driver for this to work.  The enclosure LED
scripts work for multipath devices as well.  The scripts will clear the LED
when the fault is cleared.

3. Rate limit ZIO delay and checksum events so as not to flood ZED

ZIO delay and checksum events are rate limited to 5/sec in the zfs module.

Reviewed-by: Richard Laager <rlaager@wiktel.com>
Reviewed by: Don Brady <don.brady@intel.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #2449 
Closes #3017 
Closes #5159
2016-10-19 12:55:59 -07:00
Don Brady
d02ca37979 Bring over illumos ZFS FMA logic -- phase 1
This first phase brings over the ZFS SLM module, zfs_mod.c, to handle
auto operations in response to disk events. Disk event monitoring is
provided from libudev and generates the expected payload schema for
zfs_mod. This work leverages the recently added devid and phys_path
strings in the vdev label.

Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Don Brady <don.brady@intel.com>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #4673
2016-09-01 11:39:45 -07:00