1. Enable multipath autoreplace support for FMA.
This extends FMA autoreplace to work with multipath disks. This
requires libdevmapper to be installed at build time.
2. Turn on/off fault LEDs when VDEVs become degraded/faulted/online
Set ZED_USE_ENCLOSURE_LEDS=1 in zed.rc to have ZED turn on/off the enclosure
LED for a drive when a drive becomes FAULTED/DEGRADED. Your enclosure must
be supported by the Linux SES driver for this to work. The enclosure LED
scripts work for multipath devices as well. The scripts will clear the LED
when the fault is cleared.
3. Rate limit ZIO delay and checksum events so as not to flood ZED
ZIO delay and checksum events are rate limited to 5/sec in the zfs module.
Reviewed-by: Richard Laager <rlaager@wiktel.com>
Reviewed by: Don Brady <don.brady@intel.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes#2449Closes#3017Closes#5159
This first phase brings over the ZFS SLM module, zfs_mod.c, to handle
auto operations in response to disk events. Disk event monitoring is
provided from libudev and generates the expected payload schema for
zfs_mod. This work leverages the recently added devid and phys_path
strings in the vdev label.
Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Don Brady <don.brady@intel.com>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes#4673