Commit Graph

4 Commits

Author SHA1 Message Date
bunder2015
bf6ca0a631 shellcheck pass
note: which is non-standard. Use builtin 'command -v' instead. [SC2230]
note: Use -n instead of ! -z. [SC2236]

Reviewed-by: George Melikov <mail@gmelikov.ru>
Reviewed-by: Giuseppe Di Natale <guss80@gmail.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: bunder2015 <omfgbunder@gmail.com>
Closes #8367
2019-02-04 09:07:19 -08:00
Tony Hutter
3e9c9d8a89 Add SMART self-test results to zpool status -c
Add in SMART self-test results to zpool status|iostat -c.  This
works for both SAS and SATA drives.

Also, add plumbing to allow the 'smart' script to take smartctl
output from a directory of output text files instead of running
it against the vdevs.

Reviewed-by: Giuseppe Di Natale <dinatale2@llnl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #7178
2018-02-27 09:31:27 -08:00
bunder2015
ca0b376604 Add SMART attributes for SSD and NVMe
This adds the SMART attributes required to probe Samsung SSD and NVMe
(and possibly others) disks when using the "zpool status -c" command.

Reviewed-by: loli10K <ezomori.nozomu@gmail.com>
Reviewed-by: Giuseppe Di Natale <dinatale2@llnl.gov>
Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: bunder2015 <omfgbunder@gmail.com>
Closes #7183 
Closes #7193
2018-02-21 13:52:47 -08:00
Giuseppe Di Natale
099700d9df zpool iostat/status -c improvements
Users can now provide their own scripts to be run
with 'zpool iostat/status -c'. User scripts should be
placed in ~/.zpool.d to be included in zpool's
default search path.

Provide a script which can be used with
'zpool iostat|status -c' that will return the type of
device (hdd, sdd, file).

Provide a script to get various values from smartctl
when using 'zpool iostat/status -c'.

Allow users to define the ZPOOL_SCRIPTS_PATH
environment variable which can be used to override
the default 'zpool iostat/status -c' search path.

Allow the ZPOOL_SCRIPTS_ENABLED environment
variable to enable or disable 'zpool status/iostat -c'
functionality.

Use the new smart script to provide the serial command.

Install /etc/sudoers.d/zfs file which contains the sudoer
rule for smartctl as a sample.

Allow 'zpool iostat/status -c' tests to run in tree.

Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Giuseppe Di Natale <dinatale2@llnl.gov>
Closes #6121 
Closes #6153
2017-06-05 10:52:15 -07:00