ZTS: Fix L2ARC test reliability
Disable depth cap (L2ARC_EXT_HEADROOM_PCT=0) in DWPD and multidev tests that rely on predictable marker advancement during fill and measurement. Rework multidev_throughput to verify sustained throughput across three consecutive windows instead of asserting an absolute rate. Use larger cache devices (8GB) to avoid frequent global marker resets (smallest_capacity/8), fill ARC before attaching caches to provide a stable evictable buffer pool, and lower write_max to 8MB/s to avoid exhausting data within the measurement period. Use destroy_pool (log_must_busy) instead of log_must zpool destroy to handle transient EBUSY during teardown. Remove l2arc_multidev_throughput_pos from the expected-fail list in zts-report.py.in. Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Alexander Motin <alexander.motin@TrueNAS.com> Signed-off-by: Ameer Hamza <ahamza@ixsystems.com> Closes #18321
This commit is contained in:
@@ -245,7 +245,6 @@ maybe = {
|
||||
'history/history_010_pos': ['SKIP', exec_reason],
|
||||
'io/mmap': ['SKIP', fio_reason],
|
||||
'l2arc/l2arc_l2miss_pos': ['FAIL', known_reason],
|
||||
'l2arc/l2arc_multidev_throughput_pos': ['FAIL', 18272],
|
||||
'l2arc/persist_l2arc_005_pos': ['FAIL', known_reason],
|
||||
'largest_pool/largest_pool_001_pos': ['FAIL', known_reason],
|
||||
'mmap/mmap_sync_001_pos': ['FAIL', known_reason],
|
||||
|
||||
Reference in New Issue