189 lines
4.8 KiB
C
189 lines
4.8 KiB
C
// SPDX-License-Identifier: GPL-2.0
|
|
/* Driver for the Texas Instruments DP83TG720 PHY
|
|
* Copyright (c) 2023 Pengutronix, Oleksij Rempel <kernel@pengutronix.de>
|
|
*/
|
|
#include <linux/bitfield.h>
|
|
#include <linux/kernel.h>
|
|
#include <linux/module.h>
|
|
#include <linux/phy.h>
|
|
|
|
#define DP83TG720S_PHY_ID 0x2000a284
|
|
|
|
/* MDIO_MMD_VEND2 registers */
|
|
#define DP83TG720S_MII_REG_10 0x10
|
|
#define DP83TG720S_STS_MII_INT BIT(7)
|
|
#define DP83TG720S_LINK_STATUS BIT(0)
|
|
|
|
#define DP83TG720S_PHY_RESET 0x1f
|
|
#define DP83TG720S_HW_RESET BIT(15)
|
|
|
|
#define DP83TG720S_RGMII_DELAY_CTRL 0x602
|
|
/* In RGMII mode, Enable or disable the internal delay for RXD */
|
|
#define DP83TG720S_RGMII_RX_CLK_SEL BIT(1)
|
|
/* In RGMII mode, Enable or disable the internal delay for TXD */
|
|
#define DP83TG720S_RGMII_TX_CLK_SEL BIT(0)
|
|
|
|
#define DP83TG720S_SQI_REG_1 0x871
|
|
#define DP83TG720S_SQI_OUT_WORST GENMASK(7, 5)
|
|
#define DP83TG720S_SQI_OUT GENMASK(3, 1)
|
|
|
|
#define DP83TG720_SQI_MAX 7
|
|
|
|
static int dp83tg720_config_aneg(struct phy_device *phydev)
|
|
{
|
|
/* Autoneg is not supported and this PHY supports only one speed.
|
|
* We need to care only about master/slave configuration if it was
|
|
* changed by user.
|
|
*/
|
|
return genphy_c45_pma_baset1_setup_master_slave(phydev);
|
|
}
|
|
|
|
static int dp83tg720_read_status(struct phy_device *phydev)
|
|
{
|
|
u16 phy_sts;
|
|
int ret;
|
|
|
|
phydev->pause = 0;
|
|
phydev->asym_pause = 0;
|
|
|
|
/* Most of Clause 45 registers are not present, so we can't use
|
|
* genphy_c45_read_status() here.
|
|
*/
|
|
phy_sts = phy_read(phydev, DP83TG720S_MII_REG_10);
|
|
phydev->link = !!(phy_sts & DP83TG720S_LINK_STATUS);
|
|
if (!phydev->link) {
|
|
/* According to the "DP83TC81x, DP83TG72x Software
|
|
* Implementation Guide", the PHY needs to be reset after a
|
|
* link loss or if no link is created after at least 100ms.
|
|
*
|
|
* Currently we are polling with the PHY_STATE_TIME (1000ms)
|
|
* interval, which is still enough for not automotive use cases.
|
|
*/
|
|
ret = phy_init_hw(phydev);
|
|
if (ret)
|
|
return ret;
|
|
|
|
/* After HW reset we need to restore master/slave configuration.
|
|
*/
|
|
ret = dp83tg720_config_aneg(phydev);
|
|
if (ret)
|
|
return ret;
|
|
|
|
phydev->speed = SPEED_UNKNOWN;
|
|
phydev->duplex = DUPLEX_UNKNOWN;
|
|
} else {
|
|
/* PMA/PMD control 1 register (Register 1.0) is present, but it
|
|
* doesn't contain the link speed information.
|
|
* So genphy_c45_read_pma() can't be used here.
|
|
*/
|
|
ret = genphy_c45_pma_baset1_read_master_slave(phydev);
|
|
if (ret)
|
|
return ret;
|
|
|
|
phydev->duplex = DUPLEX_FULL;
|
|
phydev->speed = SPEED_1000;
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int dp83tg720_get_sqi(struct phy_device *phydev)
|
|
{
|
|
int ret;
|
|
|
|
if (!phydev->link)
|
|
return 0;
|
|
|
|
ret = phy_read_mmd(phydev, MDIO_MMD_VEND2, DP83TG720S_SQI_REG_1);
|
|
if (ret < 0)
|
|
return ret;
|
|
|
|
return FIELD_GET(DP83TG720S_SQI_OUT, ret);
|
|
}
|
|
|
|
static int dp83tg720_get_sqi_max(struct phy_device *phydev)
|
|
{
|
|
return DP83TG720_SQI_MAX;
|
|
}
|
|
|
|
static int dp83tg720_config_rgmii_delay(struct phy_device *phydev)
|
|
{
|
|
u16 rgmii_delay_mask;
|
|
u16 rgmii_delay = 0;
|
|
|
|
switch (phydev->interface) {
|
|
case PHY_INTERFACE_MODE_RGMII:
|
|
rgmii_delay = 0;
|
|
break;
|
|
case PHY_INTERFACE_MODE_RGMII_ID:
|
|
rgmii_delay = DP83TG720S_RGMII_RX_CLK_SEL |
|
|
DP83TG720S_RGMII_TX_CLK_SEL;
|
|
break;
|
|
case PHY_INTERFACE_MODE_RGMII_RXID:
|
|
rgmii_delay = DP83TG720S_RGMII_RX_CLK_SEL;
|
|
break;
|
|
case PHY_INTERFACE_MODE_RGMII_TXID:
|
|
rgmii_delay = DP83TG720S_RGMII_TX_CLK_SEL;
|
|
break;
|
|
default:
|
|
return 0;
|
|
}
|
|
|
|
rgmii_delay_mask = DP83TG720S_RGMII_RX_CLK_SEL |
|
|
DP83TG720S_RGMII_TX_CLK_SEL;
|
|
|
|
return phy_modify_mmd(phydev, MDIO_MMD_VEND2,
|
|
DP83TG720S_RGMII_DELAY_CTRL, rgmii_delay_mask,
|
|
rgmii_delay);
|
|
}
|
|
|
|
static int dp83tg720_config_init(struct phy_device *phydev)
|
|
{
|
|
int ret;
|
|
|
|
/* Software Restart is not enough to recover from a link failure.
|
|
* Using Hardware Reset instead.
|
|
*/
|
|
ret = phy_write(phydev, DP83TG720S_PHY_RESET, DP83TG720S_HW_RESET);
|
|
if (ret)
|
|
return ret;
|
|
|
|
/* Wait until MDC can be used again.
|
|
* The wait value of one 1ms is documented in "DP83TG720S-Q1 1000BASE-T1
|
|
* Automotive Ethernet PHY with SGMII and RGMII" datasheet.
|
|
*/
|
|
usleep_range(1000, 2000);
|
|
|
|
if (phy_interface_is_rgmii(phydev))
|
|
return dp83tg720_config_rgmii_delay(phydev);
|
|
|
|
return 0;
|
|
}
|
|
|
|
static struct phy_driver dp83tg720_driver[] = {
|
|
{
|
|
PHY_ID_MATCH_MODEL(DP83TG720S_PHY_ID),
|
|
.name = "TI DP83TG720S",
|
|
|
|
.config_aneg = dp83tg720_config_aneg,
|
|
.read_status = dp83tg720_read_status,
|
|
.get_features = genphy_c45_pma_read_ext_abilities,
|
|
.config_init = dp83tg720_config_init,
|
|
.get_sqi = dp83tg720_get_sqi,
|
|
.get_sqi_max = dp83tg720_get_sqi_max,
|
|
|
|
.suspend = genphy_suspend,
|
|
.resume = genphy_resume,
|
|
} };
|
|
module_phy_driver(dp83tg720_driver);
|
|
|
|
static struct mdio_device_id __maybe_unused dp83tg720_tbl[] = {
|
|
{ PHY_ID_MATCH_MODEL(DP83TG720S_PHY_ID) },
|
|
{ }
|
|
};
|
|
MODULE_DEVICE_TABLE(mdio, dp83tg720_tbl);
|
|
|
|
MODULE_DESCRIPTION("Texas Instruments DP83TG720S PHY driver");
|
|
MODULE_AUTHOR("Oleksij Rempel <kernel@pengutronix.de>");
|
|
MODULE_LICENSE("GPL");
|