Kernel driver ftsteutates
|
|
=========================
|
|
|
|
Supported chips:
|
|
|
|
* FTS Teutates
|
|
|
|
Prefix: 'ftsteutates'
|
|
|
|
Addresses scanned: I2C 0x73 (7-Bit)
|
|
|
|
Author: Thilo Cestonaro <thilo.cestonaro@ts.fujitsu.com>
|
|
|
|
|
|
Description
|
|
-----------
|
|
|
|
The BMC Teutates is the Eleventh generation of Superior System
|
|
monitoring and thermal management solution. It is builds on the basic
|
|
functionality of the BMC Theseus and contains several new features and
|
|
enhancements. It can monitor up to 4 voltages, 16 temperatures and
|
|
8 fans. It also contains an integrated watchdog which is currently
|
|
implemented in this driver.
|
|
|
|
The ``pwmX_auto_channels_temp`` attributes show which temperature sensor
|
|
is currently driving which fan channel. This value might dynamically change
|
|
during runtime depending on the temperature sensor selected by
|
|
the fan control circuit.
|
|
|
|
The 4 voltages require a board-specific multiplier, since the BMC can
|
|
only measure voltages up to 3.3V and thus relies on voltage dividers.
|
|
Consult your motherboard manual for details.
|
|
|
|
To clear a temperature or fan alarm, execute the following command with the
|
|
correct path to the alarm file::
|
|
|
|
echo 0 >XXXX_alarm
|
|
|
|
Specifications of the chip can be found at the `Kontron FTP Server <http://ftp.kontron.com/>`_ (username = "anonymous", no password required)
|
|
under the following path:
|
|
|
|
/Services/Software_Tools/Linux_SystemMonitoring_Watchdog_GPIO/BMC-Teutates_Specification_V1.21.pdf
|