117 lines
5.0 KiB
ReStructuredText
117 lines
5.0 KiB
ReStructuredText
.. SPDX-License-Identifier: GPL-2.0-or-later
|
|
|
|
Kernel driver aquacomputer-d5next
|
|
=================================
|
|
|
|
Supported devices:
|
|
|
|
* Aquacomputer Aquaero 5/6 fan controllers
|
|
* Aquacomputer D5 Next watercooling pump
|
|
* Aquacomputer Farbwerk RGB controller
|
|
* Aquacomputer Farbwerk 360 RGB controller
|
|
* Aquacomputer Octo fan controller
|
|
* Aquacomputer Quadro fan controller
|
|
* Aquacomputer High Flow Next sensor
|
|
* Aquacomputer Leakshield leak prevention system
|
|
* Aquacomputer Aquastream XT watercooling pump
|
|
* Aquacomputer Aquastream Ultimate watercooling pump
|
|
* Aquacomputer Poweradjust 3 fan controller
|
|
* Aquacomputer High Flow USB flow meter
|
|
* Aquacomputer MPS Flow devices
|
|
|
|
Author: Aleksa Savic
|
|
|
|
Description
|
|
-----------
|
|
|
|
This driver exposes hardware sensors of listed Aquacomputer devices, which
|
|
communicate through proprietary USB HID protocols.
|
|
|
|
The Aquaero devices expose eight physical, eight virtual and four calculated
|
|
virtual temperature sensors, as well as two flow sensors. The fans expose their
|
|
speed (in RPM), power, voltage and current. Temperature offsets and fan speeds
|
|
can be controlled.
|
|
|
|
For the D5 Next pump, available sensors are pump and fan speed, power, voltage
|
|
and current, as well as coolant temperature and eight virtual temp sensors. Also
|
|
available through debugfs are the serial number, firmware version and power-on
|
|
count. Attaching a fan to it is optional and allows it to be controlled using
|
|
temperature curves directly from the pump. If it's not connected, the fan-related
|
|
sensors will report zeroes.
|
|
|
|
The pump can be configured either through software or via its physical
|
|
interface. Configuring the pump through this driver is not implemented, as it
|
|
seems to require sending it a complete configuration. That includes addressable
|
|
RGB LEDs, for which there is no standard sysfs interface. Thus, that task is
|
|
better suited for userspace tools.
|
|
|
|
The Octo exposes four physical and sixteen virtual temperature sensors, as well as
|
|
eight PWM controllable fans, along with their speed (in RPM), power, voltage and
|
|
current.
|
|
|
|
The Quadro exposes four physical and sixteen virtual temperature sensors, a flow
|
|
sensor and four PWM controllable fans, along with their speed (in RPM), power,
|
|
voltage and current. Flow sensor pulses are also available.
|
|
|
|
The Farbwerk and Farbwerk 360 expose four temperature sensors. Additionally,
|
|
sixteen virtual temperature sensors of the Farbwerk 360 are exposed.
|
|
|
|
The High Flow Next exposes +5V voltages, water quality, conductivity and flow readings.
|
|
A temperature sensor can be connected to it, in which case it provides its reading
|
|
and an estimation of the dissipated/absorbed power in the liquid cooling loop.
|
|
|
|
The Leakshield exposes two temperature sensors and coolant pressure (current, min, max and
|
|
target readings). It also exposes the estimated reservoir volume and how much of it is
|
|
filled with coolant. Pump RPM and flow can be set to enhance on-device calculations,
|
|
but this is not yet implemented here.
|
|
|
|
The Aquastream XT pump exposes temperature readings for the coolant, external sensor
|
|
and fan IC. It also exposes pump and fan speeds (in RPM), voltages, as well as pump
|
|
current.
|
|
|
|
The Aquastream Ultimate pump exposes coolant temp and an external temp sensor, along
|
|
with speed, power, voltage and current of both the pump and optionally connected fan.
|
|
It also exposes pressure and flow speed readings.
|
|
|
|
The Poweradjust 3 controller exposes a single external temperature sensor.
|
|
|
|
The High Flow USB exposes an internal and external temperature sensor, and a flow meter.
|
|
|
|
The MPS Flow devices expose the same entries as the High Flow USB because they have
|
|
the same USB product ID and report sensors equivalently.
|
|
|
|
Depending on the device, not all sysfs and debugfs entries will be available.
|
|
Writing to virtual temperature sensors is not currently supported.
|
|
|
|
Usage notes
|
|
-----------
|
|
|
|
The devices communicate via HID reports. The driver is loaded automatically by
|
|
the kernel and supports hotswapping.
|
|
|
|
Sysfs entries
|
|
-------------
|
|
|
|
================ ==============================================================
|
|
temp[1-20]_input Physical/virtual temperature sensors (in millidegrees Celsius)
|
|
temp[1-8]_offset Temperature sensor correction offset (in millidegrees Celsius)
|
|
fan[1-8]_input Pump/fan speed (in RPM) / Flow speed (in dL/h)
|
|
fan1_min Minimal fan speed (in RPM)
|
|
fan1_max Maximal fan speed (in RPM)
|
|
fan1_target Target fan speed (in RPM)
|
|
fan5_pulses Quadro flow sensor pulses
|
|
power[1-8]_input Pump/fan power (in micro Watts)
|
|
in[0-7]_input Pump/fan voltage (in milli Volts)
|
|
curr[1-8]_input Pump/fan current (in milli Amperes)
|
|
pwm[1-8] Fan PWM (0 - 255)
|
|
================ ==============================================================
|
|
|
|
Debugfs entries
|
|
---------------
|
|
|
|
================ =================================================
|
|
serial_number Serial number of the device
|
|
firmware_version Version of installed firmware
|
|
power_cycles Count of how many times the device was powered on
|
|
================ =================================================
|